DEV Community

Cover image for Ten cabinets wide is 1920 pixels: the pitch decision your wall size already made
Angel Huang
Angel Huang

Posted on

Ten cabinets wide is 1920 pixels: the pitch decision your wall size already made

A brief for an indoor hall usually arrives with the pitch already in it: "P2.5, twelve metres wide, launching in April." The pitch is the one number nobody questions, and it is the wrong place to start — the geometry of the wall has already decided most of the answer.

Last month I went through an AIS-series job — 960 × 960 mm cabinets, P5, rear service — in an auditorium whose nearest row sits about 19 m out. The brief said P2.5. Here is the arithmetic we ran instead.

Where a P5 pixel stops existing

Human visual acuity is about one arc minute: the angle at which two adjacent points stop resolving as separate. For a pixel of pitch p, the distance at which it subtends one arc minute is roughly p × 3,438.

  • P5: 17.2 m
  • P4: 13.8 m
  • P2.5: 8.6 m

Past 17 m a P5 pixel is smaller than your eye's resolving limit, so you are not looking at pixels any more, you are looking at an image. In a hall whose nearest seat is 19 m, P5 is not a compromise — anything finer is invisible to everyone in the room, and you paid twice: in the modules, and in the receiving cards and processing needed for four times the pixels.

The number that matters is not the depth of the hall but the distance to the nearest seat, because that is the only viewer who can see the structure.

The pixel budget: 192 per cabinet

This is the part that gets skipped. A 960 × 960 mm cabinet at P5 is 192 × 192 pixels — 36,864 per cabinet, 200 pixels per metre.

Walls are built in whole cabinets, so the pixel count falls out of the wall size. A 9.6 m × 3.84 m wall is 10 × 4 cabinets: 1,920 × 768 pixels. That is 1080p width exactly. Your 1920 × 1080 content maps one to one horizontally, no scaling, no resampling, no soft edges on text.

Now put P2.5 on the same wall: 3,840 × 1,536 pixels. Your 1080p source is upscaled 2× in each direction, so the panel invents three out of every four pixels. You have bought resolution your content cannot fill, and quadrupled the driver count behind it.

So the question before signing is not "which pitch" but "what is my content's native width, and how many cabinets does it take to hit it". If it lands on 1,920, you are finished.

Where a finer pitch earns its money

P2.5 and below are not marketing. They are correct when the front row is inside 8 m or the screen does IMAG close-ups; when the screen is on camera and the camera's resolving power, not the audience's, sets the limit; when content is text-dense and read from a few metres; or when the wall is small, because a 3 m wall at P5 is only about 600 pixels wide.

The failure mode is applying a close-viewing pitch to a long-throw room because "better is safer". It is heavier, hotter, and needs more processing per square metre.

The mechanical bill nobody quotes

A 960 × 960 mm cabinet in this series weighs about 20 kg. A 10 × 4 wall is 40 cabinets, so roughly 800 kg of screen before steel and before the rigging load. In a hall with a ceiling grid, that number decides whether you fly it or build a ground frame — worth knowing before the structural engineer does.

Rear service. These cabinets are back-service, so the rear doors need a walkway: 600 mm minimum, more if a technician kneels. If the wall goes against a solid partition, that becomes a construction item, not an AV item. Power. Input is 200–240 VAC — a normal 230 V circuit in a European or Asian hall, but the distribution still has to be planned per column.

Brightness is the least interesting number here: above 600 nits is already more than a dimmed auditorium needs, and running at 60–70% keeps the blacks clean on camera.

The four numbers to sign off

  1. Distance to the nearest seat — divide by 3,438 and you have your maximum useful pitch.
  2. Wall size in whole cabinets — multiply out and you have your pixel count.
  3. Content native width — it should match that pixel count, not exceed it.
  4. Cabinet weight × count — that is your structural load.

Put those four on one page and the pitch argument disappears — it becomes a derived value.

If your nearest seat is 19 m and your content is 1080p, would you sign a 9.6 m P5 wall at native 1,920 pixels, or a 6 m P2.5 wall that upscales? I would like to know which one your integrator actually quoted, and whether they showed you the cabinet count.

The AIS5 specification behind this piece — P5, 960 × 960 × 100 mm cabinet, 320 × 160 mm module, 1920 Hz, IP43, rear service — is on the product page: https://www.mlxled.com/product/ais5-indoor-led-display-screen-p5-for-indoor-advertising-display/

I work with MuenLED (#MuenLED).

Top comments (0)