A facilities manager in Ohio sends a photo of a 1998 lobby wall: ceiling 3.1 m, wall 4.4 m, one 20 A 120 V circuit that used to feed two vending machines.
Two weeks on, the quote argues pitch, brightness and lead time — and never answers the electrician's only question: how many amps, on how many circuits?
That gap is where indoor projects stall. Not at the pixel pitch. At the panel.
The line that decides the project is not the pitch
An indoor fixed cabinet spec sheet reads, in order: pixel pitch, module size, cabinet size, brightness, refresh rate, scan ratio, IP rating, maintenance access, and near the bottom, input voltage.
Buyers read top to bottom and stop at refresh rate. But input voltage decides whether the product fits the building at all.
A cabinet listed at 200–240 VAC is a product for a 230 V market. Put it in a 120 V building and you are not adapting it — you are arguing with the contractor, the inspector and whoever signed the panel schedule. A cabinet listed at 100–240 VAC, 50/60 Hz wide range is the same hardware in a US lobby on a 120 V branch circuit and in a German office on 230 V. No transformer, no buck-boost box bolted behind the screen, no conversation about a field-modified assembly.
The AIAF-A2.5 cabinet we build is specified that way: 100–240 VAC wide range, front service, 640×480×44 mm.
At 120 V the cost is current
Power is fixed. Current follows the voltage.
A 20 A, 120 V circuit carries 2,400 VA at the breaker rating, and most electricians load a continuous display to 80% of that — 1,920 VA — because an LED wall runs ten hours a day, not ten minutes.
At 230 V, 1,920 VA is 8.3 A. At 120 V it is 16 A. Same wall, twice the current, two circuits where you planned one.
So the North American conversation is not about brightness. It is about how many dedicated circuits exist and whether the installer can reach the cabinets. Drivers sit inside the cabinet, so every feed point is a hole planned before the drywall closes.
Ask for two power figures, not one
Every serious supplier quotes watts per square metre. Ask for two: maximum and average.
Maximum sizes the circuit and the breaker. Average sizes the HVAC.
One unlabelled figure cannot size either. Quoted on average, the wall trips a breaker on a white slide deck. Quoted on maximum, you buy an oversized air handler and a change order. In a 44 mm front-service cabinet the drivers sit inside the room's envelope, with no rear plenum to dump into — so the room's cooling load includes the screen, and that is the mechanical engineer's problem, not the AV integrator's.
Front service buys the back room and charges you the front
Front service means no rear plant room and no 800 mm corridor behind the wall. The cost is a permanent clear zone in front: a planter parked 300 mm from the screen turns a ten-minute module swap into a furniture-moving job.
Depth matters too. Surface mounted, 44 mm stands proud of the wall plus trim, which in a lift lobby reads as a framed panel. Recessed, the niche needs 44 mm plus cable bend radius and a service loop; cut it tight and the last row will not seat.
A 640×480 brick against a 16:9 expectation
AIAF-A2.5 is a 640×480 die-cast cabinet: 320×160 mm modules, 256×192 = 49,152 pixels per cabinet, P2.5, just over 600 nits, 1,920 Hz refresh, 1/32 scan, IP43, Novastar control.
A 4:3 brick does not divide into 16:9. Full HD at 2.5 mm is 1,920×1,080 px — three cabinets wide, 5.6 high. You cannot buy 0.6 of a cabinet, so the wall becomes 3×6 = 1,920×1,152 (5:3) or 3×5 = 1,920×960 (2:1), and content is letterboxed or rescaled. Not a defect — geometry, settled at drawing stage, next to the circuit count.
Five lines for the RFQ
- Input voltage, written as a range.
- Maximum and average power per square metre, labelled.
- Number and location of feed points, cabinet by cabinet.
- Service access — front, rear or both — and the clear floor zone required.
- Cabinet size and the resulting pixel grid at the real wall dimensions.
Pitch goes on line six. Answer those five in writing and the contractor stops guessing, the engineer gets a real load, and the wall in the rendering is the wall that ships.
I work with MuenLED, and AIAF-A2.5 is one of the indoor fixed cabinets we ship: 640×480×44 mm, front service, 100–240 VAC wide range, Novastar. Specs and drawings are on the product page — https://www.mlxled.com/product/aiaf2-5-indoor-led-display-with-p2-5-pixels-indoor-led-display/
So which number do you size your circuit on: the maximum figure or the average — and who on your side signs off on it?