Digital step attenuators: the settling time spec nobody reads
A digitally controlled attenuator is specified by attenuation range, step size and accuracy. All three are easy to compare and all three are usually fine.
The number that breaks systems is settling time, and it is often buried in a footnote or missing entirely.
Why settling matters more than accuracy
In an AGC loop or a leveling circuit, the attenuator is inside the feedback path. Every step change is a disturbance the loop has to absorb.
Typical sequence: the controller detects the output is 2 dB high, commands a 2 dB step, and the attenuator takes some time to actually get there. During that window the loop is open-loop and the output is wrong. If the loop bandwidth is faster than the attenuator, you get oscillation that looks exactly like a badly compensated amplifier — except the root cause is a switch.
Rule of thumb: attenuator settling should be at least ten times faster than the loop response you want. A 1 kHz loop needs settling well under 100 µs. Relay-based attenuators at 5–10 ms cannot be used there at all; solid-state parts in the 1–10 µs range can.
The three switching technologies
| Type | Settling | Life | Notes |
|---|---|---|---|
| Mechanical relay | 5–20 ms | 10⁶–10⁷ cycles | Lowest loss, best linearity, audible, wears out |
| PIN diode | 1–10 µs | unlimited | Needs bias current, higher loss, temperature drift |
| GaAs FET / SOI | 0.1–1 µs | unlimited | Lowest switching glitch, best for fast loops |
The relay is still the right answer for a calibration-grade instrument where the attenuator is set once per measurement. The solid-state part is the right answer anywhere the attenuator moves during a measurement.
Glitch is a separate spec
Even a fast attenuator can produce a transient. During the switch, the attenuation passes through intermediate states — sometimes including a state where attenuation is momentarily lower than either endpoint. In a high power chain, a 100 ns transient of 6 dB less attenuation is enough to stress a downstream amplifier.
Ask for the switching transient, not just settling time. Some parts specify "glitch < 0.5 dB" and some do not specify it at all, which tells you something.
Accuracy over temperature
A 0.5 dB step attenuator with 0.3 dB accuracy at 25 °C is common. Over -40 to +85 °C that can drift to 0.6 dB, and the drift is not uniform across steps — it is usually worst at the highest attenuation settings because that is where the most switches are in the path.
If your application does closed-loop leveling, this does not matter. If it is open-loop calibrated, ask for the temperature coefficient per step.
DB Design builds digitally controlled attenuators and phase shifters from 0.5 to 40 GHz. If you are putting one inside a leveling loop, the settling spec is the first thing worth confirming.