A customer in Spain balanced a mulcher with the Balanset-1A. Before the first run we asked to see how the sensors were installed, and received a video. The frames below are taken from it.

It shows the whole measuring chain. The two vibration sensors sit on the housing, one at each end of the rotor. The laser tachometer stands on a magnetic base on a steel plate on the floor, not on the machine, and is aimed at the drive pulley. The cables go to the measurement unit, and the unit is connected to a laptop.

Vibration sensor on the mulcher housing next to the belt pulley

Laser tachometer on a magnetic base on the floor, aimed at the drive pulley

Vibration sensor X1 on the mulcher housing

The balancing itself was completed in a later session, in two planes. Initial vibration at 1329 rpm: 16.17 and 16.00 mm/s. The program calculated correction weights of 372 g and 345 g. We advised installing less than the calculated mass first, to check how the machine responds. After the weights were welded, the vibration was below 4.8 mm/s.

More at vibromera.eu.