About
LiftMaster 811LM Encrypted DIP with Security+ 2.0 Technology Remote Control
ASIN: B0071EYRGG
FCC ID: HBW7471
IC: 2666A-7471
Teardown
Front
Back
Programming Instructions
- Push blue button (
SW4
) to put into programming mode - Verify that yellow LED (
SW5
) lights up - Push black button (
SW2
) amount of times to toggle through frequencies
# of presses | Device Security Type |
---|---|
1 | Security+ 2.0® |
2 | 315 MHz DIP |
3 | 390 MHz DIP |
- Verify that gate receivers responds (either via LED or by actual gate opening)
- Push blue button again to exit programming mode
- Verify yellow LED turns off
Top comments (0)