DEV Community

John  Ajera
John Ajera

Posted on

1

PVC Pending in Prometheus Deployment (and How to Fix It)

🚨 The Problem

When deploying Prometheus with persistence enabled, you may encounter this issue:

kubectl get pvc -n prometheus
Enter fullscreen mode Exit fullscreen mode

Bad output:

storage-prometheus-alertmanager-0   Pending
Enter fullscreen mode Exit fullscreen mode

Then describing the PVC reveals:

kubectl describe pvc storage-prometheus-alertmanager-0 -n prometheus
Enter fullscreen mode Exit fullscreen mode

Output:

no persistent volumes available for this claim and no storage class is set
Enter fullscreen mode Exit fullscreen mode

πŸ”§ Root Cause

Although your cluster may have a default storage class like gp2, Helm charts like Prometheus do not always assume one and may require you to explicitly specify it.

βœ… Solution

Specify the storage class name for both Alertmanager and Server volumes:

resource "helm_release" "prometheus" {
  name       = "prometheus"
  repository = "https://prometheus-community.github.io/helm-charts"
  chart      = "prometheus"
  version    = local.prometheus_version
  namespace  = "prometheus"
  create_namespace = false

  set {
    name  = "server.persistentVolume.storageClass"
    value = "gp2"
  }

  set {
    name  = "alertmanager.persistentVolume.storageClass"
    value = "gp2"
  }
}
Enter fullscreen mode Exit fullscreen mode

πŸ” Validation

Check if the PVCs are now bound:

kubectl get pvc -n prometheus
Enter fullscreen mode Exit fullscreen mode

Expected:

prometheus-server                   Bound     pvc-...   8Gi        RWO            gp2            ...
storage-prometheus-alertmanager-0   Bound     pvc-...   2Gi        RWO            gp2            ...
Enter fullscreen mode Exit fullscreen mode

You can also verify the storage class:

kubectl get storageclass
Enter fullscreen mode Exit fullscreen mode

Expected:

NAME   PROVISIONER             RECLAIMPOLICY   VOLUMEBINDINGMODE      ALLOWVOLUMEEXPANSION   AGE
gp2    kubernetes.io/aws-ebs   Delete          WaitForFirstConsumer   false                  ...
Enter fullscreen mode Exit fullscreen mode

🧼 Summary

When deploying stateful workloads with Helm, always check if the chart expects a specific storage class to be set. PVCs stuck in Pending are usually a hint that your StorageClass wasn't picked up properly.