DEV Community

Cover image for Aunty vs. SUPR-DSF: Should you measure particle size in every formulation or just the finalists?
Desmond Gilmour
Desmond Gilmour

Posted on

Aunty vs. SUPR-DSF: Should you measure particle size in every formulation or just the finalists?

Would you drop an ingredient that barely moved your protein's unfolding temperature? In a 2026 study from WuXi Biologics and the University of Kansas, the answer depended on which version of the protein went into the well. Lun Xin and colleagues screened 96 formulations of an Fc fusion protein on SUPR-DSF. Three cyclodextrins made no difference to when the precursor started to unfold. On the finished fusion protein, all three delayed it. A cyclodextrin made it into the optimized formulation.

Keep that story in mind. It's the best argument I know for how to compare these two instruments.

What's the real difference?

Both instruments run intrinsic differential scanning fluorimetry (DSF): they heat your protein and track its natural fluorescence as it unfolds. From that curve you get the melting temperature (Tm), where half the protein has unfolded, and the onset temperature (Tonset), where unfolding first begins. Aunty adds dynamic and static light scattering (DLS and SLS) in the same wells to size particles as they form. SUPR-DSF reads up to 384 wells in one thermal run. So which would change your next decision: a particle size in every well, or four times the wells? I know many labs that would rather have one specialized instrument focused on a single technique.

What would you do with 384 wells?

I'd keep the replicates. In a manufacturer application note, infliximab was screened against 96 formulations in triplicate on one plate in under two hours, at 10 µL per well. Some formulations raised the second melting transition more than the one the team picked. They chose a buffer that raised the first transition by 2.3 °C and the second by 1.3 °C, to protect the part of the antibody that unfolds first. A separate trastuzumab screen covered 96 formulations in under 1.5 hours.

Now picture 96 formulations plus eight controls, all in triplicate. That's 312 wells, which fits on one 384-well SUPR-DSF plate with 72 wells to spare. Aunty's specifications list 96 samples per experiment, so the same layout needs four plates and four runs.

What does a well cost?

This is where the gap really opens up. SUPR-DSF reads standard black 384-well qPCR plates under an optical seal, with no proprietary consumable. Nicoya's MSF application note puts consumables at about 4¢ a sample, roughly $14 for a whole plate. Aunty runs on its own 96-well quartz plate, which Unchained calls a consumable. Its online store lists 20 plates with seals at $6,000, or $300 a plate.

Say you only have protein for a five-point titration. On SUPR-DSF you'd fill five wells, leave 379 empty, and still spend about a twenty-fifth of what one Aunty plate costs. Scale up to the 312-well screen and it's one SUPR-DSF plate against four Aunty plates: about $14 versus $1,200 at list.

Can a three-cent well be trusted?

That was my first worry about a plastic plate. Cohrs and colleagues tested it directly in Molecular Pharmaceutics. Background from the plate and seal was negligible, spectra were comparable to quartz cuvettes on a separate spectrofluorometer, and black plates gave less Tm variation than white ones. Across 6,096 lysozyme measurements, Tm averaged 74.6 °C with a standard deviation of 0.17 °C.

This is the part I love: the full curve catches what a single number misses. In a manufacturer study of β-lactoglobulin, 96 buffer conditions were run four times each on one plate. At pH 4.5 and pH 6.0 the Tm values were less than 1 °C apart, yet onset at pH 6.0 came about 15 °C earlier. One number made the buffers look interchangeable. The full curve showed pH 6.0 was less stable.

If your protein is very heat-stable, range matters too. SUPR-DSF ramps from 10 to 105 °C, while Aunty's published range is 15 to 95 °C. Those extra ten degrees give a late transition room to finish.

Did the screen predict storage?

Back to the cyclodextrins. Xin's team paired SUPR-DSF with a separate PEG solubility assay, refined the formulation with a designed experiment, then stressed it. The optimized formulation showed much better resistance to aggregation, fragmentation and subvisible particles under accelerated stress, including shaking and up to four weeks at 40 °C. The melt told them what to test, and the stress study confirmed it held up.

What if two melts look equally good?

Then I'd ask what happens when they cool. Modulated scanning fluorimetry (MSF) heats each well in steps, returns it to a reference temperature after every step, and checks whether the fluorescence recovers. The temperature where recovery starts to fail is the nonreversibility onset temperature (Tnr). MSF is built directly into SUPR-DSF, and underneath it's the same measurement as a standard melt. It reads the same intrinsic fluorescence, just with a different temperature program. That's what a specialized instrument buys you: more answers from the one technique it's built for.

Why care? In Nicoya's MSF application note, a human IgG started losing its ability to recover at 63.7 °C, while DLS didn't flag aggregation until 70.3 °C. That's one antibody, and the order can flip for others, which is exactly why a recovery measurement adds something size alone can't.

Do you need DLS in every well?

Unchained Labs gives a good example. Adding arginine made bovine IgG unfold earlier, yet delayed the temperature at which its measured particle diameter doubled from 70.2 °C to 72.7 °C.

There’s also precedent for using a dedicated DLS instrument for a narrower question. Ginkgo Bioworks and collaborators profiled the thermostability of 246 antibodies using SUPR-DSF. Separately, they used a DynaPro III to measure concentration-dependent self-association in 10 antibodies in one buffer and five in another. That experiment measured how diffusion changed with concentration. For a lab that needs particle size throughout heating, I’d check whether its existing DLS supports the required temperature program and sampling frequency.

Thermal screening can also distinguish samples that look similar after purification. In a study of anti-CD20 antibody variants, Hale and colleagues reported no significant aggregation by HPLC immediately after purification. Yet 30 of 51 IgG1 variants had a significantly lower onset or first melting temperature than wild type on SUPR-DSF.

Which would I choose?

For a formulation team picking a handful of conditions from dozens or hundreds, I'd choose SUPR-DSF. You get replicates that make a small shift believable, full curves that show which transition an ingredient protects, 3¢ wells, and an overnight recovery check for the close calls.

Here's my buying test. Lay out your last real formulation screen with every control and replicate. Would a particle size in every well have changed the decision? Or would you have learned more from a second construct on the same plate? Those 72 spare wells hold 24 more conditions in triplicate. That's the same comparison that kept a cyclodextrin in the WuXi–Kansas formulation.


Desmond Gilmour

Email: dgilmour@nicoyalife.com

Phone: +1 519-546-9876

I work at Nicoya Lifesciences. The views expressed here are my own and do not necessarily reflect those of Nicoya. This is a personal publication, not an official company communication.

Aunty is a trademark of Unchained Labs.

Sources

Prices as listed on November 26, 2026. Unchained's store shows prices in $ with no currency code.