DEV Community

Cover image for SUPR-DSF or Prometheus Panta: Which Three Buffers Go in the Fridge?
Desmond Gilmour
Desmond Gilmour

Posted on

SUPR-DSF or Prometheus Panta: Which Three Buffers Go in the Fridge?

You have 96 formulations of an antibody and enough material to put three into a storage study. One buffer protects the part of the antibody that unfolds first. Another pushes the later transition higher. A third looks good on both, but you wonder whether it's quietly starting to aggregate. Which three vials go in the fridge?

That's the question I'd put to any lab weighing SUPR-DSF against NanoTemper's Prometheus Panta. Both run intrinsic differential scanning fluorimetry (DSF): they heat your protein and follow its natural tryptophan and tyrosine fluorescence as it unfolds, with no dye. From that curve you get the melting temperature (Tm), where half the protein has unfolded, and the onset temperature (Tonset), where unfolding first begins. Panta adds dynamic light scattering (DLS), which sizes particles as they form, plus static light scattering and a turbidity readout. SUPR-DSF specializes in fluorescence and does it across a full 384-well plate.

Why does the transition you track matter so much?

Here's my favourite example. In an Applied Photophysics application note, infliximab unfolded in two stages, at 68 °C and 83 °C. The team screened 96 formulations in triplicate on one 384-well plate at 10 µL per well. After a one-hour rest at room temperature, the measurement took under two hours.

The winner was a salt-based buffer at pH 7.2. It raised the first transition by 2.3 °C and the second by 1.3 °C. Other buffers did more for the second transition, but the team chose to protect the domain that unfolds first. Sort that spreadsheet by the biggest Tm jump and a different buffer goes into storage.

That's why I love having every condition, replicate and control on the same ramp. When the call comes down to a degree or two on one peak, you want a true side-by-side.

What does 96 in triplicate look like on each bench?

Ninety-six formulations in triplicate is 288 measurements. On SUPR-DSF, that fits on one plate with 96 wells to spare for blanks, a reference antibody and extra repeats. Panta's specifications list up to 48 capillaries, or one 24-capillary chip, per run. The same screen takes six full runs before you add a single control.

Time follows the same math. At 1 °C/min, a 20 to 95 °C ramp takes 75 minutes on either instrument. SUPR-DSF does that once for all 288 wells. Panta does it six times, whether you load by hand or with NanoTemper's optional robotic autosampler. That adds up to about 7.5 hours of ramping before loading and cool-down.

SUPR-DSF Prometheus Panta
Sample holder Standard black 384-well qPCR plate plus optical seal Glass capillaries, single or in 24-capillary chips
Measurements per run Up to 384 Up to 48
288-measurement screen One run, 96 wells spare Six full runs
Consumables for 288 (US list) US$14.50 (one plate, one seal) US$291.06 (288 standard capillaries)

What does each measurement cost?

SUPR-DSF reads commercially available 384-well qPCR plates, so there's no proprietary consumable. Applied Photophysics lists the black Azenta FrameStar 4ti-0386 plate. LabSource lists it at US$418.50 for 50, or US$8.37 a plate. LPS lists Azenta's 4ti-0560 optical seal at US$612.56 for 100, or US$6.13 a seal. That's US$14.50 per sealed plate, about 3.8¢ a well when full. I used the highest seal listing I found, so I'm not lowballing.

Panta's standard capillaries (NanoTemper PR-C002) are listed by Fisher Scientific at US$404.25 for 400, about US$1.01 each. They're single-use glass and get discarded after the run. For 288 measurements, that's US$291.06 against US$14.50, about 20 times more. Prices were accessed November 26, 2026, and your contract pricing may differ.

Both formats use about 10 µL per measurement, so protein use is a wash. What the plate changes is how freely you can spend positions on replicates, blanks and a common reference.

Can a plastic plate be trusted?

Until recently, intrinsic DSF "has been almost exclusively performed in glass capillaries or (micro)cuvettes," as Cohrs and colleagues at Ghent University, Protein Stable and TU Munich note in Molecular Pharmaceutics, so they tested plates directly (using Bio-Rad black plates). Background from the plate and seal was negligible, and spectra were comparable to quartz cuvettes on a separate spectrofluorometer. Across 6,096 lysozyme measurements, Tm averaged 74.6 °C with a standard deviation of 0.17 °C. That's one protein and one protocol, not a head-to-head with capillaries, so ask both vendors to run your protein in your buffer at the same ramp rate and compare the replicate spread.

Here's a detail I geek out on. SUPR-DSF records the full emission spectrum from 310 to 420 nm in every well, so you can analyse intensity, wavelength ratios or the spectrum's centre of mass. Panta reads at 330 and 350 nm and reports their ratio. When a curve looks odd, I like having the whole spectrum on file.

What if two buffers tie?

Then I'd ask what happens when they cool down. Modulated scanning fluorimetry (MSF) heats each sample in steps, returns it to a reference temperature after every step, and checks whether the fluorescence recovers. The temperature where recovery starts to fail is the nonreversibility onset temperature (Tnr). It's the same intrinsic fluorescence as a standard melt, just a different temperature program.

Many labs I talk to prefer an instrument that specializes in one technique, and this is a big reason why: MSF gets more answers out of the exact measurement SUPR-DSF is built for. Panta can cycle temperature too, through a separately activated software mode. The difference is scale. Nicoya's application note runs MSF on a full plate of up to 384 samples overnight, in about 16 to 18 hours, and Cohrs and colleagues ran MSF in 384-well plates in their study too. A Panta run tops out at 48 capillaries.

Why bother? In that note, a human IgG began losing recovery at 63.7 °C, while DLS on a separate instrument flagged particle growth at 70.3 °C. For an antibody fragment, the order flipped: particle growth at 63.8 °C, loss of recovery at 70.2 °C. So recovery and particle size answer different questions.

Do you need particle sizing in the first round?

I'd save it for the finalists. Ginkgo Bioworks and collaborators profiled 246 antibodies, 106 of them approved and most others in clinical trials. They measured thermostability on SUPR-DSF for all 246 and DLS-based self-association on only 10. Thermal data on everything, scattering for the short list. If you already have DLS in the building, it can handle your three finalists.

So which one fits your lab?

For a lab that regularly picks a handful of formulations from 96, I'd recommend SUPR-DSF. Every buffer, replicate and reference goes on one plate in one ramp, for US$14.50 in consumables at list, with full spectra for every well and an overnight MSF plate for the close calls.

Here's a quick test I'd suggest. Take your last formulation screen, with every control and replicate, and count the runs it would need on each instrument. Then ask yourself: would a particle size for every sample have changed which three vials went in the fridge, or would more replicates on the first transition have made the call easier? Once your three are picked, Nicoya's Revo or Alto SPR systems can check that the antibody still binds its target after storage.


Desmond Gilmour

Email: dgilmour@nicoyalife.com

Phone: +1 519-546-9876

I work at Nicoya Lifesciences. The views expressed here are my own and do not necessarily reflect those of Nicoya. This is a personal publication, not an official company communication.

NanoTemper, Prometheus and nanoDSF are trademarks of NanoTemper Technologies GmbH. Prometheus Panta is a NanoTemper Technologies product.

Sources

Prices accessed November 26, 2026.

Top comments (0)